Cro | Cr2O3 | CrO3 | Cr2S3 | Cr2(SO4)3 | K2CrO4 | PbCrO4 | CrF3 | Cr3C2 | CrB | CrN | CrSi | CrSi2 | SS-304 | Basic |
XPS Spectra
Chromium (Cr) Compounds
The XPS Spectra section provides raw and processed survey spectra, chemical state spectra, BE values, FWHM values, and overlays of key spectra.
Atom% values from surveys are based on sample, as received, and Scofield cross-sections. Atom% values are corrected for IMFP and PE.
Peak-fits are guides for practical, real-world applications. Peak-fits are not fully optimized or designed to test any theory.
Chromium Oxide (Cr2O3)
Survey, Peak-fits, BEs, FWHMs, and Peak Labels
→ Periodic Table | → Six (6) BE Tables |
Survey Spectrum from Cr2O3 Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag (3d5/2) FWHM = 1.3 eV |
|
|
|
→ Periodic Table | → Six (6) BE Tables |
Cr (2p) Spectrum from Cr2O3 – Raw Fresh exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
Cr (2p3/2) Spectrum from Cr2O3 – Peak-Fit Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
|
Cr (2p3/2) Spectrum from Cr2O3 – Raw – Expanded Fresh exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
Cr (2p) Spectrum from Cr2O3 – Raw – Vertically Expanded Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
|
→ Periodic Table | → Six (6) BE Tables |
O (1s) Spectrum from Cr2O3 – Raw Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
O (1s) Spectrum from Cr2O3 – Peak-Fit Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
|
→ Periodic Table | → Six (6) BE Tables |
O (1s) Spectrum from Cr2O3 – Raw – Extended Range Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
O (1s) Spectrum from Cr2O3 – Raw – Vertically Expanded Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
|
→ Periodic Table | → Six (6) BE Tables |
C (1s) Spectrum from Cr2O3 – Raw Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
C (1s) Spectrum from Cr2O3 – Peak-Fit Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
→ Periodic Table | → Six (6) BE Tables |
Cr (3p) Spectrum from Cr2O3 – Raw Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
Cr (3p) Spectrum from Cr2O3 – Peak-Fit Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
|
→ Periodic Table | → Six (6) BE Tables |
Cr (3s) Spectrum from Cr2O3 – Raw Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
Cr (3s) Spectrum from Cr2O3 – Peak-Fit Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
|
→ Periodic Table | → Six (6) BE Tables |
Auger Signals from Cr2O3 – Raw Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
Valence Band Signals from Cr2O3 – Raw Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
|
Overlays |
|
→ Periodic Table | → Six (6) BE Tables |
Valence Band Spectra – Overlay of Cro and Cr2O3 Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
Cr (2p) Spectra – Overlay of Cro and Cr2O3 Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
|
→ Periodic Table | → Six (6) BE Tables |
Cr (2p) Spectra – Overlay of Cro, Cr native oxide, and Cr2O3 Freshly exposed bulk, Flood gun is ON, C (1s) BE = 285.0 eV, Ag FWHM = 0.75 eV |
|
End-of-spectra Price to purchase raw data sets:
Transmission Function Tests |
December 2015 – Transmission Function of Thermo K-Alpha Plus |
→ Periodic Table |
Survey Spectra of Ion Etched Copper (Cr), PEs = 50, 100, 150 and 200 eV |
|
→ Periodic Table |
March 2016 – Transmission Function of Thermo K-Alpha Plus |
Survey Spectra of Ion Etched Copper (Cr), PEs = 100, 150 and 200 eV |
|
→ Periodic Table |
August 2019 – Transmission Function of Thermo K-Alpha Plus |
Survey Spectra of HOPG (C), PEs = 20, 50, 100 and 200 eV |
|
→ Periodic Table |
January 2022 – Transmission Function of Thermo K-Alpha Plus |
Survey Spectra of Ion Etched Copper (Cr), PEs = 100, 120, 140, 160, 180 and 200 eV |
End-of-page